Perfect UPS back up system for your Ultrasound equipment.

Description

This high frequency, true online, double-conversion UPS is suitable for high availability situations and mission critical equirements. It offers double CPU control, optional SNMP remote management and a front panel LCD for easy configuration. The UPS also has the capability of extending the runtime with the addition of an external battery pack.

AC OUTPUT

  • AC Output Voltage 100V/110V/115V/120V
  • AC Output Capacity 2000VA, 1400 Watts
  • AC Output Frequency 50Hz/60Hz (Auto detection)
  • AC Output Frequency Stability (+/-0.5%)
  • AC Output Voltage Regulation (+/-2%)
  • AC Output Powerfactor 0.7 (lagging)
  • AC Output Hamonic distortion <3% of T.H.D. at linear load
  • AC Output Overload detection 105% for 10 seconds and 130% +/- 10% for 300ms

TRANSFER

  • Transfer Power failure Recovery 0 ms

NOISE

  • Noise Level 1m Distance < 45dBA

PROTECTION

  • Protection Spike 150 Joules

BATTERY

  • Battery Type Sealed lead acid battery, free-maintenance
  • Battery Protection Cut off without draining any current when battery low
  • Battery DC Voltage 48V

BACKUP TIME

  • Battery Backup Time Full Load 9 minutes
  • Battery Backup Time Half Load 25 minutes
  • Battery Recharge Time About 8 hours to 90% after fully discharged

PHYSICAL

  • Physical Weight 70.4 lbs, 32 kg.
  • Physical Dimension 192x460x385 mm

INDICATORS

  • LCD Indicators Status Line input (green), inverter output (green), bypass (yellow), fault (red)

ALARMS

  • Alarm Battery Discharge The first warning will beep every 4 seconds to indicate battery in use. The second warning will beep every 1 second to signal battery low condition
  • Alarm UPS Fault Continuous beeping sound

INTERFACES

  • Interface Dry Contacts provide power management & diagnostic functions including power status, battery low, schedule UPS ON/OFF, battery/load level display and more. Compatatible with Windows 95/98/2000/ME/NT/XP, Novell Unix and other popular systems
  • Interface RS-232 Provide power management & diagnostic functions including power status, battery low, schedule UPS ON/OFF, battery/load level display and more. Compatatible with Windows 95/98/2000/ME/NT/XP, Novell Unix and other popular systems

Powercom ULT-2000LCD Ultimate 2000VA 1400 Watts Online Double Conversion Extended Runtime Tower UPS - Retail

Manufacturer: Powercom USA
MFR Part #: ULT-2000LCD / ULT-2000
Condition:
New
Warranty: 2-Year Manufacturer Warranty

More Powercom Products

Perfect UPS back up system for your Ultrasound equipment.

Description

This high frequency, true online, double-conversion UPS is suitable for high availability situations and mission critical equirements. It offers double CPU control, optional SNMP remote management and a front panel LCD for easy configuration. The UPS also has the capability of extending the runtime with the addition of an external battery pack.

AC OUTPUT

  • AC Output Voltage 100V/110V/115V/120V
  • AC Output Capacity 2000VA, 1400 Watts
  • AC Output Frequency 50Hz/60Hz (Auto detection)
  • AC Output Frequency Stability (+/-0.5%)
  • AC Output Voltage Regulation (+/-2%)
  • AC Output Powerfactor 0.7 (lagging)
  • AC Output Hamonic distortion <3% of T.H.D. at linear load
  • AC Output Overload detection 105% for 10 seconds and 130% +/- 10% for 300ms

TRANSFER

  • Transfer Power failure Recovery 0 ms

NOISE

  • Noise Level 1m Distance < 45dBA

PROTECTION

  • Protection Spike 150 Joules

BATTERY

  • Battery Type Sealed lead acid battery, free-maintenance
  • Battery Protection Cut off without draining any current when battery low
  • Battery DC Voltage 48V

BACKUP TIME

  • Battery Backup Time Full Load 9 minutes
  • Battery Backup Time Half Load 25 minutes
  • Battery Recharge Time About 8 hours to 90% after fully discharged

PHYSICAL

  • Physical Weight 70.4 lbs, 32 kg.
  • Physical Dimension 192x460x385 mm

INDICATORS

  • LCD Indicators Status Line input (green), inverter output (green), bypass (yellow), fault (red)

ALARMS

  • Alarm Battery Discharge The first warning will beep every 4 seconds to indicate battery in use. The second warning will beep every 1 second to signal battery low condition
  • Alarm UPS Fault Continuous beeping sound

INTERFACES

  • Interface Dry Contacts provide power management & diagnostic functions including power status, battery low, schedule UPS ON/OFF, battery/load level display and more. Compatatible with Windows 95/98/2000/ME/NT/XP, Novell Unix and other popular systems
  • Interface RS-232 Provide power management & diagnostic functions including power status, battery low, schedule UPS ON/OFF, battery/load level display and more. Compatatible with Windows 95/98/2000/ME/NT/XP, Novell Unix and other popular systems
    Shipping

    Free Standard shipping on all US orders for many products.
    Orders placed before 12PM PST will be shipped on the same business day. Most orders will be shipped within 1 business day and should arrived between 1-5 business days.
    We also provide Overnight, 2nd Day deliveries for additional charges. You can calculate the shipping costs by adding the items into your cart.

    Returns & Warranty

    30 Day Hassle Free Returns. Warranty varies from manufacturers. Please contact us for more information.