Powercom VGD-1000RM Vanguard (2U) 1000VA 6+0 Outlets RS-232 & USB Port
  • 99% Shipped the same day
  • New products
    Daily
  • Payment
    Secure System
  • Buy more
    Pay less

Powercom VGD-1000RM Vanguard (2U) 1000VA 6+0 Outlets RS-232 & USB Port

Available: In Stock
  • Product SKU: VGD-1000RM
$479.99

Powercom VGD-1000RM Vanguard (2U) 1000VA 6+0 Outlets RS-232 & USB Port Rackmount UPS - Retail

Manufacturer: Powercom USA
MFR Part #: VGD-1000RM
Condition: New
Warranty: 2 Year Manufacturer Warranty

More Powercom Products

Save $15.00 with this Powercom Rebate!!!

***Note: If you need 230V model, please call first.

Description

GENERAL INFORMATION
Model Type VANGUARD RM
Model Name VGD-1000RM /
VGD-1000LCDRM

AC INPUT
AC Input Capacity on Battery 1000VA
AC Input Voltage 100V or 110V/120V/127V
AC Input Frequency 50/60 Hz +/-0.5%

AC OUTPUT
AC Output Waveform Sinewave
AC Output Voltage 100V or 110V/120V/127V
AC Output Frequency 50/60 Hz +/-0.5%
AC Output Transfer 0 ms
AC Output Efficiency >95%
AC Output Hamonic distortion <3% of T.H.D. at linear load
AC Output Crest factor ratio 3 : 1

PROTECTION
Protection Spike 260 Joules
Protection Surge Protection 120V (IEEE C62.41)
Protection Overload Protection 125% for 1 minutes and 150% for 10 seconds
Protection Short Circuit UPS output cut off immediately or input fuse/circuit breaker protection

BATTERY
Battery Type sealed, maintenance-free lead acid batteries
Battery Typical Recharge time to 90% full: 4 hours
Battery Protection cut off without draining any current when battery is low

BACKUP TIME
Battery Backup Time Full Load 1u=4 min, 2u=7 min
Battery Backup Time Half Load 1u=10 min, 2u=15 min

PHYSICAL
Physical Weight kgs RM 2u=17.1
Physical Weight lbs RM 2u=37.6
Physical Shipping Weight kgs 2u=19.3
Physical Shipping Weight lbs 2u=42.5
Physical Dimension mm RM 2u=428x425x84
Physical Dimension inch RM 2u=16.9x16.7x3.3
Physical Input Inlet NEMA5-15P (120V)
Physical Receptacles NEMA5-15R (120V)

INDICATOR
Indicator LCD Input/output voltage, frequency, on-line mode, back up mode, battery capacity, load level

ALARM
Alarm Battery Backup Beep every 5 sec
Alarm UPS Fault Continuous beeping sound and LCD display

CONFORMANCE
Conformance Safety UL 1778, CE

INTERFACE
Interface RS-232 Serial Port & USB
Interface Option SNMP card

ENVIRONMENT
Environment Temperature -20 ~ 50C / -4 ~ 122F
Environment Humidity 0 - 95%, non-condensing
Environment Operation Temperature 0 - 40C / 32 - 104F
Environment Operation Elevation 3500 meters max

Powercom VGD-1000RM Vanguard (2U) 1000VA 6+0 Outlets RS-232 & USB Port Rackmount UPS - Retail

Manufacturer: Powercom USA
MFR Part #: VGD-1000RM
Condition: New
Warranty: 2 Year Manufacturer Warranty

More Powercom Products

Save $15.00 with this Powercom Rebate!!!

***Note: If you need 230V model, please call first.

Description

GENERAL INFORMATION
Model Type VANGUARD RM
Model Name VGD-1000RM /
VGD-1000LCDRM

AC INPUT
AC Input Capacity on Battery 1000VA
AC Input Voltage 100V or 110V/120V/127V
AC Input Frequency 50/60 Hz +/-0.5%

AC OUTPUT
AC Output Waveform Sinewave
AC Output Voltage 100V or 110V/120V/127V
AC Output Frequency 50/60 Hz +/-0.5%
AC Output Transfer 0 ms
AC Output Efficiency >95%
AC Output Hamonic distortion <3% of T.H.D. at linear load
AC Output Crest factor ratio 3 : 1

PROTECTION
Protection Spike 260 Joules
Protection Surge Protection 120V (IEEE C62.41)
Protection Overload Protection 125% for 1 minutes and 150% for 10 seconds
Protection Short Circuit UPS output cut off immediately or input fuse/circuit breaker protection

BATTERY
Battery Type sealed, maintenance-free lead acid batteries
Battery Typical Recharge time to 90% full: 4 hours
Battery Protection cut off without draining any current when battery is low

BACKUP TIME
Battery Backup Time Full Load 1u=4 min, 2u=7 min
Battery Backup Time Half Load 1u=10 min, 2u=15 min

PHYSICAL
Physical Weight kgs RM 2u=17.1
Physical Weight lbs RM 2u=37.6
Physical Shipping Weight kgs 2u=19.3
Physical Shipping Weight lbs 2u=42.5
Physical Dimension mm RM 2u=428x425x84
Physical Dimension inch RM 2u=16.9x16.7x3.3
Physical Input Inlet NEMA5-15P (120V)
Physical Receptacles NEMA5-15R (120V)

INDICATOR
Indicator LCD Input/output voltage, frequency, on-line mode, back up mode, battery capacity, load level

ALARM
Alarm Battery Backup Beep every 5 sec
Alarm UPS Fault Continuous beeping sound and LCD display

CONFORMANCE
Conformance Safety UL 1778, CE

INTERFACE
Interface RS-232 Serial Port & USB
Interface Option SNMP card

ENVIRONMENT
Environment Temperature -20 ~ 50C / -4 ~ 122F
Environment Humidity 0 - 95%, non-condensing
Environment Operation Temperature 0 - 40C / 32 - 104F
Environment Operation Elevation 3500 meters max

    Shipping

    Free Standard shipping on all US orders for many products.
    Orders placed before 12PM PST will be shipped on the same business day. Most orders will be shipped within 1 business day and should arrived between 1-5 business days.
    We also provide Overnight, 2nd Day deliveries for additional charges. You can calculate the shipping costs by adding the items into your cart.

    Returns & Warranty

    30 Day Hassle Free Returns. Warranty varies from manufacturers. Please contact us for more information.